Dräger X-am 5100 Hydrogen Chloride (HCl) Gas Detector
Technical Specifications
Detailed Description
Product Overview
The Dräger X-am 5100 Hydrogen Chloride (HCl) Gas Detector is a compact, intrinsically safe portable gas detector designed for accurate HCl gas monitoring. Featuring advanced electrochemical sensor technology, it is ideal for chemical processing, metal treatment, laboratories, pharmaceutical manufacturing, and industrial safety applications. Dräger X-am 5100 Hydrogen Chloride (HCl) Gas Detector SEO Short Description The Dräger X-am 5100 Hydrogen Chloride (HCl) Gas Detector is a robust single-gas detector engineered for continuous monitoring of Hydrogen Chloride (HCl). Equipped with Dräger's high-performance XS electrochemical sensor, it delivers rapid response, exceptional accuracy, and reliable protection in hazardous industrial environments. Product Description The Dräger X-am 5100 Hydrogen Chloride (HCl) Gas Detector is specifically designed for the detection of Hydrogen Chloride (HCl), a highly corrosive and toxic gas commonly encountered in chemical manufacturing, metal processing, pharmaceutical production, and laboratory environments. Its innovative gas-entry system minimizes gas adsorption, enabling rapid response times and accurate measurement of highly reactive gases. Powered by the proven Dräger XS electrochemical HCl sensor, the detector ensures dependable personal protection with continuous real-time monitoring. The X-am 5100 features a lightweight ergonomic design, intuitive operation, integrated datalogging, and multiple alarm functions, making it an excellent choice for industrial hygiene, process safety, and hazardous material applications.
Key Features
- Dedicated Hydrogen Chloride (HCl) gas detection
- Advanced Dräger XS electrochemical HCl sensor
- Fast response with reduced gas adsorption
- Continuous real-time gas monitoring
- Lightweight and ergonomic handheld design
- Large backlit LCD display
- Audible, visual (360° LED), and vibration alarms
- Integrated event and data logger
- Rechargeable NiMH or replaceable alkaline battery options
- Infrared interface for configuration and data download
- Rugged industrial construction
- Intrinsically safe for hazardous areas
- Long operating time (up to 180 hours)
- Easy bump testing and calibration
- Low maintenance with long sensor life
Applications
- Chemical Manufacturing
- Hydrochloric Acid Production
- Metal Pickling and Surface Treatment
- Steel Processing Plants
- Pharmaceutical Manufacturing
- Laboratory Safety
- Petrochemical Plants
- Fertilizer Industry
- Water Treatment Facilities
- Industrial Maintenance
- Hazardous Material (HazMat) Response
- Personal Exposure Monitoring
- Process Safety Monitoring
- Environmental Health & Safety (EHS)
- Emergency Response Teams
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | Dräger X-am 5100 HCl |
| Detector Type | Portable Single Gas Detector |
| Target Gas | Hydrogen Chloride (HCl) |
| Measuring Range | 0 – 30 ppm |
| Sensor Technology | Dräger XS Electrochemical Sensor |
| Measuring Principle | Electrochemical |
| Display | Backlit LCD |
| Alarm Types | Audible, Visual (360° LED), Vibration |
| Data Logger | Yes |
| Battery Options | Rechargeable NiMH / Replaceable Alkaline |
| Operating Time | Up to 180 hours (battery dependent) |
| Charging Time | Approximately 4 hours |
| Operating Temperature | -20°C to +50°C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Atmospheric Pressure | 700–1300 mbar |
| Protection Rating | IP54 |
| Communication | Infrared Interface |
| Calibration | Manual and Automatic |
| Intrinsic Safety | ATEX, IECEx, CSA and other international approvals |
| Dimensions | 48 x 130 x 61 mm |
| Weight | Approx. 220 g |